The delta primary transposed zigzag secondary dtz transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. Zag grounding transformer a pv facility with 1 mva inverter total ac nameplate is interconnected to a. Groundingzigzag transformers quality transformer and. Applications of zigzag transformers to reduce harmonics in. This example discusses the use of the zigzag transformers in power systems to provide a high impedance ground system for the delta connected or ungrounded. The most common connection used in grounding transformers is the zig zag connection. The zigzag transformer has been used some years ago for creating a neutral, thereby converting a three wire distribution system to a fourwire system. This is the purpose of the earthing transformer, which could consist of a zig zag winding, or a twowinding star delta transformer where the star winding of correct voltage supplies an accessible neutral point when connected to the supply system. Zig zag transformer offers low impedance path to zero sequence components under fault conditions so it can be perfectly used as earthing transformer with and earthing reference. The artificial neutral creates a lowimpedance path for the zerosequence current and highimpedance path for the positivesequence current. Calculate neutral earthing transformer secondary current. Zigzag grounding transformers post glover resistors. Pdf zigzag transformer is only used as a grounding transformer in a three phase delta connected power supply system.
Both the 3phase and singlephase loads may be supplied with the rated. Effective grounding zigzag transformer mike holts forum. Other means are now more common, such as 6 phase star. Each core leg of the zigzag transformer has two coils wound on it. It can be order as a custom three phase unit or as 3 individual single phase units. Calculate required resistance value at secondary side rsec. Regardless of the configuration, star, delta or zigzag, the measurements are normally made phase to phase and comparisons are made to the estimated ratios defined by the transformer template voltages and configuration. The zig zag transformer has been used some years ago for creating a neutral, thereby converting a three wire distribution system to a fourwire system. It is used as a grounding transformer, creating a missing neutral connection from an ungrounded 3phase system to permit the grounding of that neutral to an earth reference point. The dtz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. Grounding transformers are used for obtaining a grounded neutral on three phase, threewire systems, providing a return path for zero sequence current generated by the loads in the system or by the fault currents. The zigzag transformer can be combined with either star or delta connections in twowinding transformer, in this application only the deltazigzag winding is used. We performed a shorted secondary test on the zigzag transformer which gave us a transformer impedance of zo.
I generally see zigzag transformers used with wyeg. Even though this type of transformer connection is not useful in transforming power, it has many features needed in todays power generation systems. Earthing transformers neutral earthing transformers. Calculate size of neutral earthing transformer netexcel. This connection has some of the features of the y and the. With the zigzag transformer, you typically insert a resistor between the neutral point and ground to limit ground fault current on the system. The common portion of an autotransformer low voltage is the common winding, and the remainder is the series winding.
Where and why do we use grounding transformer zigzag. Calculate required grounding resistor value at primary side rp. Zigzag grounding transformers are more common than a grounded wye delta transformer because they are smaller in size. Together these make up the high voltage side of the transformer. Most grounding transformers use zigzag windings but it is not the only configuration used. Transformer a has an impedance of 4%, transformer b which is to be parallel to a must have an impedance between the limits of 3. A zigzag transformer is a specialpurpose transformer with a zigzag or interconnected star. This can take the form of either a grounding transformerzigzag transformer or a neutral ground reactor. Earthing transformers, neutral earthing transformers. If the earthing current has to be limited under fault conditions, a suitable resistor can be placed in zig zag neutral terminal. Each phase, therefore, couples with each other phase and the voltages cancel out.
From this we calculated the transformer reactance for 60 hz x60. Pdf zigzag transformer some new applications with a. Each zigzag grounding bank would still have to be protected by overcurrent relays 51 as shown in figure 12 or differential relays. Three phase transformer winding configurations and. You can use the zigzag transformer in two winding transformer applications, where you obtain voltage transformation and isolation with the zigzag feature. In terms of installation, do we just need to tie the a, b, c phases of the zigzag to the distribution transformer secondaries and then ground the derived neutral of the. Custom dry type zig zag transformers zig zag transformers are a special purpose three phase transformer used in power systems. Threephase earthing transformer in zigzag configuration. In addition, impedance values of each transformer must be within 7. Calculate neutral earthing transformer xr ratio calculate fault current through neutral single line to ground fault if calculate rating of neutral earthing. We performed a shorted secondary test on the zig zag transformer which gave us a transformer impedance of zo. Comments about the use of a zigzag transformer to reduce the. Grounded wye grounded zigzag transformer connection. This paper describes the modeling of zigzag grounding transformer wound core type with varying degrees of complexity.
This article will the address the use of the zig zag transformer. The transformer being referred to by this article is called grounding transformer or earthing transformer in europe and the article should be named accrdingly to avoid confusion to readers. It provides insulation between the ground and the component so that the component may not be affected by the fault currents. The grounding transformer is commonly referred to by this connection type, the zigzag transformer. Zigzag grounding transformers specification for zigzag grounding transformers scope this specification covers design, manufacture and testing of low or mediumvoltage zigzag grounding transformers for use with neutral grounding resistors ngr for installation indoors or outdoors onto a concrete pad or power transformer. Wyeg and ngrs used with wyeg elta, although im not sure of the exact reasons behind that. The zigzag transformer is a special type of 3 phase transformer. Grounding transformers are used for obtaining a grounded neutral on three phase, threewire systems, providing a return path for zero sequence current generated.
Neutral earthing transformer is having zig zag interstar winding to achieve the required zero phase impedance. In this paper, an electrical model of a threephase transformer connected in grounded wye grounded zigzag configuration is developed, based in the common. Zigzag transformers used to be employed to enable size reductions in drive motor systems due to the stable wave form they present. The earthing transformer block models a threephase zigzagconnection earthing or grounding transformer. What exactly is the purpose of a zigzag transformer. Winding 2 zigzag r2 l2 the resistance and leakage inductance of the windings 2 of the singlephase transformers used to implement the primary winding of the zigzag phaseshifting transformer. The simulation results show that a the zigzag transformer can effectively attenuate the neutral current and zerosequence harmonic currents on the utility side. The current trend in wind farm designs is toward the wye connected primary with a delta secondary.
The block allows you to provide an artificial neutral in an ungrounded threephase power system. Analysis of zigzag transformer applying in the threephase four. Pdf design of delta primary transposed zigzag secondary. A zigzag transformer functions to provide a grounding source for ungrounded power systems as shown in the following 1line and 3line sketches. The primary and secondary windings of a transformer can be connected in different configuration as shown to meet practically any requirement. Each leg of a grounding transformer carries onethird of the neutral current and has linetoneutral voltage. The factor that influences how is share the neutral current is the impedance of the paths. The zigzag connection is also called the interconnected star connection. In the case of three phase transformer windings, three forms of connection are possible. If there is a zero sequence impedance of transformer, the power and leakage impedance rating. Design of delta primary transposed zigzag secondary dtz. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils.
A zigzag transformer may also be used to rebuild a balanced 3phase load voltage by isolating the faulty phase from the load. The goal of installing a zigzag transformer is to share the neutral current. I believe both would fall under the general category of impedance grounding. Pdf zigzag transformer some new applications with a note to. Three phase transformer winding configurations and differential relay compensation pdf. If there is a zero sequence impedance of transformer, the power and leakage impedance rating of the transformer may be calculated.
Each core leg of the zig zag transformer has two coils wound on it. I have a utility requesting effective grounding for a system behind a grounded wye grounded wye distribution transformer. The grounding transformer is one of most important equipment in power energy system. The first coil on each core is connected contrariwise to the second coil. The zigzag transformer is typically the least costly of the above three transformers mentioned. The first coil on each core is connected contrariwise to the second coil on the next core. The most common connection used in grounding transformers is the zigzag connection. A properly applied zigzag transformer keeps the neutral current local, eliminates triplen harmonics zerosequence currents from the phase currents. This article will the address the use of the zigzag transformer.
Comments about the use of a zigzag transformer to reduce. Grounding transformers are used for obtaining a grounded neutral on three phase, threewire systems, providing a return path for zero sequence current generated by the loads in the system or by the fault. The zig zag transformer is typically the least costly of the above three transformers mentioned. Zigzag transformer winding mc5w electrical 6 oct 04 23. Zig zag grounding transformers are more common than a grounded wye delta transformer because they are smaller in size. A grounding bank uses either a zigzag or wyedelta transformer which represents a high impedance. A zigzag transformer is used for providing grounding on the transformer. Design of zig zag earthing transformer in an 11kv system ralphchristie electrical 6 dec 07 09.
A zigzag transformer is more efficient than a grounded wyedelta transformer. This application note is focusing on using transformer turn ratio measurements for diagnostic purposes. Effective grounding for pv plants srcw00101 3 p a g e due to their simplicity and cost effectiveness, grounding banks are widely used to provide effective grounding in three phase three wire systems. File sharing on the engtips forums is outsourced to. They are mostly used to obtain a ground connection in a delta circuit.